rotary pump
tag class
Template Information
Template details and description
- Template Type
- tag class
- Is Abstract?
- Description
- A positive displacement pump that consists of a chamber containing gears, cams, screws, vanes, plungers or similar elements actuated by relative rotation of the drive shaft or casing and which has no separate inlet and outlet valves.
Equipment Template
Required equipment properties
Property | Data Type | Max Length | Required | Unit of Measure | Picklist |
---|---|---|---|---|---|
density Number Required | Required | ||||
design specification Text Required Max Length: 40 | 40 | Required | |||
explosion protection gas group Text Required Max Length: 40 Picklist: explosion protection gas group | 40 | Required | explosion protection gas group | ||
explosion protection temperature class Text Required Max Length: 40 Picklist: explosion protection temperature class | 40 | Required | explosion protection temperature class | ||
explosion protection zone Text Required Max Length: 40 Picklist: zone | 40 | Required | zone | ||
fluid name Text Required Max Length: 100 Picklist: fluid | 100 | Required | fluid | ||
immersed Boolean Required Max Length: 3 | 3 | Required | |||
insulation class Text Required Max Length: 40 Picklist: electrical insulation class | 40 | Required | electrical insulation class | ||
lower limit ambient operating temperature Number Required | Required | ||||
lower limit design temperature Number Required | Required | ||||
lower limit operating inlet pressure Number Required | Required | ||||
lower limit operating outlet pressure Number Required | Required | ||||
lower limit operating temperature Number Required | Required | ||||
lower limit operating volume flow rate Number Required | Required | ||||
net positive suction head available Number Required | Required | ||||
normal operating dynamic viscosity Number Required | Required | ||||
normal operating inlet pressure Number Required | Required | ||||
normal operating inlet temperature Number Required | Required | ||||
normal operating outlet pressure Number Required | Required | ||||
normal operating temperature Number Required | Required | ||||
normal operating volume flow rate Number Required | Required | ||||
operation continuous intermittent Text Required Max Length: 40 Picklist: operation continuous intermittent | 40 | Required | operation continuous intermittent | ||
operation single/parallel Text Required Max Length: 40 Picklist: operation type | 40 | Required | operation type | ||
orientation Text Required Max Length: 100 | 100 | Required | |||
pump type Text Required Picklist: pump type | Required | pump type | |||
test medium Text Required Max Length: 40 Picklist: test medium | 40 | Required | test medium | ||
test pressure Number Required | Required | ||||
upper limit ambient operating temperature Number Required | Required | ||||
upper limit design pressure Number Required | Required | ||||
upper limit design temperature Number Required | Required | ||||
upper limit operating inlet pressure Number Required | Required | ||||
upper limit operating outlet pressure Number Required | Required | ||||
upper limit operating temperature Number Required | Required | ||||
upper limit operating volume flow rate Number Required | Required |