direct current motor
equipment class
Template Information
Template details and description
- Template Type
- equipment class
- Is Abstract?
- Description
- An electric motor for operation by direct current.
- Synonyms
- CFIHOS IDCFIHOS-30000820
- IFC Class
- 14224 CodeEMDC
- UNSPSC Code
- PCA RDS Code
Equipment Template
Required equipment properties
Property | Data Type | Max Length | Required | Unit of Measure | Picklist |
---|---|---|---|---|---|
ATEX category Text Required Max Length: 40 Picklist: ATEX category | 40 | Required | ATEX category | ||
ATEX explosive atmosphere Text Required Max Length: 40 Picklist: ATEX explosive atmosphere | 40 | Required | ATEX explosive atmosphere | ||
ATEX group Text Required Max Length: 40 Picklist: ATEX group | 40 | Required | ATEX group | ||
bearing lubrication Text Required Max Length: 40 Picklist: electric motor bearing lubrication | 40 | Required | electric motor bearing lubrication | ||
dry weight Number Required | Required | ||||
efficiency Number Required | Required | ||||
explosion protection concept Text Required Max Length: 40 Picklist: explosion protection concept | 40 | Required | explosion protection concept | ||
explosion protection examination certificate number Text Required Max Length: 40 Picklist: explosion protection examination certificate number | 40 | Required | explosion protection examination certificate number | ||
explosion protection gas group Text Required Max Length: 40 Picklist: explosion protection gas group | 40 | Required | explosion protection gas group | ||
explosion protection material group Text Required Picklist: explosion protection material group | Required | explosion protection material group | |||
explosion protection notified body Text Required Max Length: 40 Picklist: explosion protection notified body | 40 | Required | explosion protection notified body | ||
explosion protection temperature class Text Required Max Length: 40 Picklist: explosion protection temperature class | 40 | Required | explosion protection temperature class | ||
explosion protection zone Text Required Max Length: 40 Picklist: zone | 40 | Required | zone | ||
frame size Text Required Max Length: 40 | 40 | Required | |||
ingress protection Text Required Max Length: 40 Picklist: ingress protection | 40 | Required | ingress protection | ||
rated current Number Required | Required | ||||
rated output power Number Required | Required | ||||
rated speed Number Required | Required | ||||
rated voltage Number Required | Required | ||||
starting current Number Required | Required |
Related Templates
These templates are related
Name | Type | Description |
---|---|---|
direct current motor tag class | tag class | An electric motor for operation by direct current. |
electric motor tag class | tag class | An electric machine for transforming electric energy into mechanical energy. |